Anomaly Detection
HydroNode checks every reading the moment it arrives. It compares the value with your own targets, with published guidelines and with what it has learned is normal for this measurement. Anything unusual becomes an incident on the sensor page and in the Incident Feed.
What a reading is compared with
How HydroNode learns what is normal
For each measurement HydroNode builds a model from the last 28 days of hourly averages. Recent days count more than old ones. It learns a typical level and, once there is enough data, a daily pattern, so a warm afternoon is not flagged just because the night was cool. The model is rebuilt every 15 minutes.
| Stage | Needs | What changes |
|---|---|---|
| First reading | Nothing | Targets and guidelines are checked. |
| Learned band | 20 readings over at least 6 hours | Statistical checks start. |
| Daily pattern | 3 days with good coverage | Time of day is taken into account. |
| Full pattern | 7 days | The daily pattern is fully trusted. |
Single outliers do not shift what counts as normal. A new level that stays stable for 6 hours is accepted, for example after you move the sensor. A new level that breaks a target or guideline is never accepted: air that is always bad stays bad.
What HydroNode can find
| Type | When it triggers |
|---|---|
| Abrupt change | A sudden jump far outside the learned band. It only counts if the next reading confirms it, so a single glitch is ignored. |
| Persistent deviation | The value stays clearly outside the band for at least 15 minutes. |
| Gradual drift | A slow, steady shift in one direction over several hours. This describes the data; it does not claim the sensor needs calibration. |
| Target breach | The value is outside the target you set. |
| Reference breach | A published guideline is exceeded, for example CO₂ above a ventilation value. |
| Recovery failure | An expected return does not happen. Example: humidity is still above 65 % an hour after a shower. |
| Data quality | Impossible values, or a value that normally moves but has not changed in 6 hours and 30 readings. |
Some patterns are recognised but are not anomalies: likely ventilation, watering, a shower, battery charging, a counter reset and the normal daily cycle. They give context and do not alert you.
Measurements without statistical checks
Weather and sky values change with the weather, not with your setup: UV, solar radiation, light, wind, rain and air pressure. They are not judged against a learned band, but guidelines such as the WHO UV index still apply. Pollutants like CO₂ and particulate matter are only flagged when they rise, never when the air gets cleaner.
One incident per problem
A problem that keeps going stays one incident. New readings update it instead of opening new ones.
- 1OpenThe problem was confirmed.
- 2OngoingIt is still there. Severity can go up, but it never silently goes down.
- 3RecoveringValues are back in range.
- 4ResolvedAfter at least two good readings and 10 minutes. Missing data never resolves an incident.
On the sensor page
The Anomalies panel on the right of the sensor page lists the incidents of this sensor in three tabs: Open, Watch and Resolved. Click an incident to see the trigger value, the rule, the readings around it and what to do. Below the list sits the latest AI explanation. At the bottom, History opens past analyses and Thresholds opens every range of the sensor in one window.
All sensors in one list
Operations › Anomalies opens the Incident Feed. The Operations panel also shows the anomalies of the last 24 hours by hour. It collects the incidents of every sensor you can see.
- 1Get the overviewThe activity chart shows incidents over 24h, 7d, 30d or 90d. Below it you see Open right now, Action required, Reviewed and Sensors affected.
- 2Narrow it downFilter by Sensor, Category and State.
- 3Open a rowIt shows the Reading, what was Expected, the Severity and the Status, plus First seen and Last seen. Telemetry shows the readings around it, Open sensor takes you to the sensor page.
What you can change
Open the sensor page and press Settings at the top right. The detection settings sit under Analysis on the left. The owner and people with Can manage change them. Everyone the sensor is shared with sees the same results.
Sensitivity
Go to Anomaly detection, or use the Anomaly detection tile on the sensor page and press Save. Sensitivity widens or narrows the learned band. Below the levels you see how many anomalies the last 7 days produced. After a busy week HydroNode suggests a calmer level, for example Use Relaxed.
| Level | Band | Good for |
|---|---|---|
| Very relaxed | 2.0× | Only extreme outliers. |
| Relaxed | 1.5× | Clear deviations only. |
| Standard | 1.25× | Default. Balanced for rooms, gardens and greenhouses. |
| Strict | 1.0× | Flags smaller deviations. |
| Very strict | 0.8× | Flags every noticeable change. |
Sensitivity only affects the learned band. Your targets and published guidelines always stay exactly as they are.
Limits and targets
- 1Open the sectionGo to Limits and targets. Each measurement shows the guideline that applies to it. Without a range of your own it says Learned from your readings.
- 2Set your rangePress Set range and switch on Use my own range. Ideal from and Ideal up to are your target, Warn below and Warn above are where it gets serious. More options adds critical limits and timing. Press Save range.
- 3Test it on the pastTry it on past data works out how many alerts your ranges would have raised. Pick a time span and press Run. Nothing is sent and nothing changes.
Shortcut: Thresholds at the bottom of the Anomalies panel opens the ranges of all measurements in one window. For ranges that change with a crop's growth, use a target profile: it writes these ranges for you, phase by phase.
Environment
Under General, set the Environment to Indoor, Outdoor or Greenhouse (treated like indoor). This changes what counts as normal. Used for picks recommendations that fit, for example for a bedroom, and Time zone is used for daily patterns. For battery readings, set the Battery type under Battery. Without it, voltage is shown as a plain reading and never raises a battery incident.
Rate incidents
Under Your verdict, in the Incident Feed or in an incident opened on the sensor page, rate it Normal, Issue or Fault (the sensor was wrong). Rated incidents count as Reviewed. When the owner rates an incident as Issue or Fault, that time is left out of learning, so the problem never becomes the new normal. Normal lets HydroNode learn from it. Ratings by people you shared the sensor with stay personal and do not change the model.